Banatton High Frequency Industrial tribus gradibus X ~ 200Kva Online UPS
Descriptio
Brand: Banatton
Locus originis: China
Typus: online UPS
Exemplar Number: BNT900-33 10~200KVA
Phase: Tres Phase
Waveform: purus sine fluctus
Transfer tempus: 0ms
Potentia factor: 0.9
Facultas: 10KVA-200KVA
Praesidium: brevis circuitus, super voltages, nexus inverso praesidio
Altera / ODM: Sic
Supple Facultates: 2000 Piece/Paxa per Month
Packaging: Carton or wood box sarcina or as you asked
Features
1. High frequency and true geminus-conversion.
2. DSP technology praestat summus perficientur
3. Lata input range (110-300 VAC);
4. Output potentia factor 0.9;
5. Active vim correctionis in omnibus gradibus
6. 50Hz/60Hz frequency modus convertentis
7. ECO modus operandi pro industria salutaris
8. Accepit dualem potestatem inputs
9. Subitis potentia off munus.
10. generator compatible
11. SNMP+USB+RS-232 plures communicationes
12. 3-scaena extendable praecipiens consilium pro optimized altilium perficiendi.
13. Novifacta altilium numero
14. sustentationem bypass praesto
15. Libitum N+X parallela redundantia.
16. Transformator solitudo libitum plenam solitudinem et sonum communem plenarium offert.
Parva Hint
1. In warantia periodo machina quaestionem habet, pete virgam venditionum, erimus responsales servitii emptoris.
2. Excedere ad tempus warantum, operationem indecens et damnum manufactum, adhuc auxilium et auxilium dabimus, pretio parce partes praestabimus.
3. Iuxta emptoris necessitates, inconventionales praebere possumus, sed sumptus leviter altiores sunt quam apparatus traditus.
Applications
Data processus centrum, Systema exercitum, servientes Computer, Medical, negotiatio, Electricitas, IT, Industriales et aliae industriae.
Factory productio linea
Packaging
EXEMPLUM | BNT9010S(H)-33* | BNT9020S(H)-33* | BNT9030S(H)-33* | BNT9040S(H)-33* | BNT9060H-33 | BNT9080H-33 | BNT9100H-33 | BNT9120H-33 | BNT9160H-33 | BNT9200H-33 | |
PERIODO | III, tempus in / III, tempus e | ||||||||||
CAPAX | 10KVA /9KW | 20KVA/18KW | 30KVA/27KW | 40KVA/36KW | 60KVA/54KW | 80KVA/72KW | 100KVA/90KW | 120KVA/108KW | 160KVA/144KW | 200KVA/180KW | |
PARALLEL FACULTAS | usque ad III unitates in parallel | usque ad II unitates in parallel | |||||||||
INPUT | |||||||||||
Nominal Voltage | 3 x 400 VAC (3Ph+N) | ||||||||||
Voltage Range | 190-520 VAC (3-phase) @ 100% load;305-478 VAC (3-phase) @ 100% load | 208-478 VAC (3-phase) @ 70% load;305-478 VAC (3-phase) @ 100% load | |||||||||
Frequentia Range | 46~54 Hz vel 56~64Hz | 40~70Hz | |||||||||
Potestas Factor | 0.99 @ 100% Load | ||||||||||
REFERO | |||||||||||
Output intentione | 3 x 360*/380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | |||||||||
AC Voltage Ordination (Batt. Modus) | ± 1% | ||||||||||
Frequentiam dolor (Synchronised dolor) | 46~54Hz vel 56~64Hz | ||||||||||
Frequency Range (Batt. Modus) | 50 Hz ± 0.1 Hz vel 60 Hz± 0.1 Hz | ||||||||||
Current Crest Ratio | 3:1 (max.); | ||||||||||
Harmonic Distortion | ≤2 % THD (Linear Load);≤4% THD (Locus Non linear) | ≤2 % THD (Linear Load);≤4% THD (Locus Non linear) | |||||||||
Transfer Tempus | Zero | ||||||||||
Inverter ad bypass | Zero | ||||||||||
Waveform (Batt. Modus) | Purus sine unda | ||||||||||
ONERO | AC Modus | 100-110% pro 10 min, 110-130% pro 1 min,>130% pro 1 secundo | 105-110% pro 1 hr, 111-125% pro 10 min, 126-150% pro 1 min, >150% pro 200ms | ||||||||
Pugna Modus | 100-110% pro 30 secundis, 110-130% pro 10 secundis; | 105-110% pro 1 hr, 111-125% pro 10 min, 126-150% pro 1 min, >150% pro 200ms | |||||||||
PRAESTANTIA | |||||||||||
AC Modus | 95.50% | 94.00% | |||||||||
ECO Modus | 97.00% | 98.00% | |||||||||
Pugna Modus | 93.50% | 93.00% | |||||||||
PUGNA | |||||||||||
Standard Model | Numeri | (16+16) pcs x 1 chorda | (16+16) pcs x 2 chordarum | N/A | |||||||
Typical Recharge Tempus | IX horas recuperandam ad XC% facultatem | ||||||||||
Incurrentes Current (max.) | 1A/2A/3A/4A (Adjustable) | ||||||||||
dato intentione | +/-218 VDC ± 10% | ||||||||||
Donec cursus Model | Type altilium | Secundum facultatem gravida externa | |||||||||
Numeri | XXXII ~ PCs XL (Adjustable) | ||||||||||
Incurrentes Current (max.) | 1A/2A/3A/4A (Adjustable) Parallelable usque ad 3 patina boards usque ad maximum 12A | 2A/4A/6A/8A (Adjustable) Parallelable usque ad 3 mutatoria tabulae dualis patina ad maximam 24A | 24A | 32A | 40A | 48A | |||||
dato intentione | +/- 13.65V x N (N=16~20) | +/- 13.7V x N (N = 16~20) | |||||||||
INDICATORS | |||||||||||
LCD Display | UPS status, onus gradu, altilium gradu, input / Output intentione, officium timer, et culpae conditiones | X "Tange Type color LCD | |||||||||
PHYSICAL | |||||||||||
Standard Model | Dimensio, D x W x H (mm). | 627 x 250 x 750 | 815 x 300 x 1000 | N/A | |||||||
Net Pondus (kg) | 129 | 144 | 225 | 250 | |||||||
Donec cursus Model | Dimensio, D x W x H (mm). | 627 x 250 x 750 | 815 x 300 x 1000 | 790 x 360 x 1010 | 940 x 567 x 1015 | 1040 x 567 x 1452 | |||||
Net Pondus (kg) | 33 | 48 | 60 | 61 | 108 | 113 | 199 | 234 | 306 | 340 | |
ENVIRONMENT | |||||||||||
Operatio Temperature | 0-40°C | ||||||||||
operatio Umor | <95% et non-considentes | ||||||||||
sonitus Level | Minus than55dB@ 1 Meter | Minus quam 60dB @ I metri | Minus quam 70dB @ I metri | Minus quam 75dB @ I metri | Minus quam 70dB @ I metri | Minus quam 73dB @1 Meter | |||||
MAGISTERIUM | |||||||||||
Dolor RS-232 / USB | Sustinet Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux et MAC. | ||||||||||
Libitum SNMP | Potestas procuratio ex SNMP procurator et web pasco |