OEM/ODM Factory Single Phase OEM Manufacturer Online 2kVA/3kVA 220V Rack Mount AC Online UPS
Qualitas prima est; officia praecipuum est; organization est cooperatio" est nostra parva negotiatio philosophica quae a societate nostra regulariter observatur et prosequitur OEM/ODM Factory Single Phase OEM Manufacturer Online 2kVA/3kVA 220V Rack Mount AC Online UPS, Praeterea nostra firmissima adhaeserit ad qualitatem et sumptus parabilis; et magnas OEM societates multis notis inlustribus exhibemus.
Qualitas prima est; officia praecipuum est; ordo est cooperatio" nostra parva negotiatio philosophica, quae a nostro comitatu regulariter observatur et prosequiturChina Power Supple and High Quality Online UPS for Data Center , districtum qualitatem temperantiae systematis constituimus. Reditus et commutatio consilium tenemus, et intra VII dies post calvariam recipere potes si in nova statione est et servitutem emendandi gratis pro fructibus et solutionibus nostris servimus. Vide ut libere nos tangas pro ulteriore notitia, si quaestiones habes. Libenter omnes clientes laborare sumus.
Descriptio
Brand: Banatton
Locus originis: China
Typus: online UPS
Exemplar Number: BNT900-RT 1~30KVA
Exhibe: LED
Phase: Una / Tres Phase
Waveform: pura sine fluctu
Transfer tempus: 0ms
Facultas: 1KVA -30KVA
Tutela: brevis circuitus, super voltages, nexus contra tutelam
Altera / ODM: Sic
Facultates copia: (X) Piece / Mass per mense
Packaging: Carton box package or as request
Features
Productum Propono
1. OEM&ODM officia accepta.
2. Sortem agentis cooperante navigio mari vel aere.
3. 1annus warantum, si quaestio qualitas sit, partes gratis dabimus.
Applications
Data processus centrum, Systema exercitum, servientes Computer, Medical, negotiatio, Electricitas, IT, Industriales et aliae industriae.
Factory productio linea
Packaging
Qualitas prima est; officia praecipuum est; organization est cooperatio" est nostra parva negotiatio philosophica quae a societate nostra regulariter observatur et prosequitur OEM/ODM Factory Single Phase OEM Manufacturer Online 2kVA/3kVA 220V Rack Mount AC Online UPS, Praeterea nostra firmissima adhaeserit ad qualitatem et sumptus parabilis; et magnas OEM societates multis notis inlustribus exhibemus.
Altera / ODM FactoryChina Power Supple and High Quality Online UPS for Data Center , districtum qualitatem temperantiae systematis constituimus. Reditus et commutatio consilium tenemus, et intra VII dies post calvariam recipere potes si in nova statione est et servitutem emendandi gratis pro fructibus et solutionibus nostris servimus. Vide ut libere nos tangas pro ulteriore notitia, si quaestiones habes. Libenter omnes clientes laborare sumus.
EXEMPLUM | BNT9010S(H)-R-31 | BNT9015S(H)-R-31 | BNT9020S(H)-R-31 | |
PERIODO | III, tempus in / I, tempus e | |||
CAPAX | 10000VA/9000W | 15000 VA/13500 W | 20000 VA / 18000 W | |
INPUT | ||||
Nominal Voltage | 3 x 400 VAC (3Ph+N) | |||
Voltage Range | 190-520 VAC (3-phase) at 50% onere; 305-478 VAC (3-phase) at 100% load | |||
Frequentia Range | 46~54 Hz vel 56~64Hz | |||
Potestas Factor | ≥ 0.99 @ 100% Load | |||
THDi |
| |||
REFERO | ||||
Output intentione | 208/220/230/240VAC | |||
AC Voltage Ordination (Batt. Modus) | ±1% | |||
Frequentiam dolor (Synchronised dolor) | 46~54Hz vel 56~64Hz | |||
Frequency Range (Batt. Modus) | 50 Hz ± 0.1 Hz vel 60 Hz± 0.1 Hz | |||
Current Crest Ratio | 3:01 | |||
Harmonic Distortion | ≤ 2 % THD (Locus Linear); ≤ V% THD (Locus Non linear) | |||
TRANSFERENDIS | AC Mode to Batt. Modus | Zero | ||
Tempus | Inverter ad bypass | Zero | ||
Waveform (Batt. Modus) | Purus Sinewave | |||
PRAESTANTIA | ||||
AC Modus | 90.50% | 91% | ||
ECO Modus | 96% | 96% | ||
Pugna Modus | 87% | 88% | ||
PUGNA | ||||
Type altilium | 12 V / 9 Ah | |||
Standard Model | Numeri | 20 (18 – 20 quam at pede. | 20 quam at pede x 2 chordis (18 - 20 quam at pede * Novifacta) | |
Typical Recharge Tempus | IX horas recuperandam ad XC% facultatem | |||
Incurrentes Current (max.) | 1A | 2A | ||
dato intentione | 273 VDC ± 1%. | |||
Donec cursus Model | Type altilium | Secundum facultatem gravida externa | ||
Numeri | ||||
Incurrentes Current (max.) | 4A | |||
dato intentione | 273 VDC ± 1%. | |||
INDICATORS | ||||
LCD Display | UPS status, onus gradu, altilium gradu, input / Output intentione, officium timer, et culpae conditiones | |||
TUMULTUS | ||||
Pugna Modus | Singulis canentes IV seconds | |||
Humilis altilium | Omnis sonans secundo | |||
ONERO | Singulis bis canentes secundo | |||
Culpam | continuo sonans | |||
PHYSICAL | ||||
Standard Model | Dimensio, D x W x H (mm). | UPS unit:668 x 438 x 133 [3U] | UPS unit:668 x 438 x 266 [6U] | |
Pugna pack: 580 x 438 x 133 [3U] | Pugna pack: 580 x 438 x 133 [3U] x 2PCS | |||
Net Pondus (kg) | UPS unitatis: 22 | UPS unitatis: 45 | ||
Pugna sarcina: 63 | Pugna pack: 63 x 2 pcs | |||
Donec cursus Model | Dimensio, D x W x H (mm). | 668 x 438 x 133 [3U] | 668 x 438 x 266 [6U] | |
Net Pondus (kg) | vigintiduo | 45 | ||
ENVIRONMENT | ||||
operating Umor | 0-95 % RH @ 0- 40°C (Non-condensing) | |||
sonitus Level | Minus quam 60dB @ I metri | Minus quam 65dB @1 metri | ||
MAGISTERIUM | ||||
Dolor RS-232 / USB | Sustinet Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux et MAC. | |||
Libitum SNMP | Potestas procuratio ex SNMP procurator et web pasco |