Factory Price 0.5~ 800kVA UPS 220/380VAC pro Industry et Commercial Field, PC, Computer/It Room, Data Centre Power Supple
In statu eximie excellenti inter emptores nostros delectamur pro eximio mercatura bonae qualitate, ultro pretium tag et maximum auxilium pro Factory Price 0.5~ 800kVA UPS 220/380VAC pro Industriis et Campo Commerciali, PC, Computer/It Room, Data Center Potestatem, unumquemque temporis, notum habuimus in omnibus particularibus, ut singulas res felices a nostris consumerent.
Laetamur in statu eximie excellenti inter emptores nostros propter eximium mercaturam bonam qualitatem, incremento tag et maximum subsidium.Sina UPS et Online UPS His omnibus subsidiis, omnibus emptoribus servire possumus cum qualitate uber et opportuna navigia cum gravissimis officiis. Cum adulescens societas increscens non optimum esse poteramus, sed optimum nostrum socium bonum esse temptavimus.
Features
Parva Hint
1. In warantia periodo machina quaestionem habet, pete virgam venditionum, erimus responsales servitii emptoris.
2. Excedere ad tempus warantum, operationem indecens et damnum factum hominis, adhuc auxilium et auxilium dabimus, pretio parce partes praestabimus.
3. Iuxta emptoris necessitates, inconventionales praebere possumus, sed sumptus leviter altiores sunt quam apparatus traditus.
Applications
Data processus centrum, Systema exercitum, servientes Computer, Medical, negotiatio, Electricitas, IT, Industriales et aliae industriae.
Factory productio linea
Packaging
In statu eximie excellenti inter emptores nostros delectamur pro eximio mercatura bonae qualitate, ultro pretium tag et maximum auxilium pro Factory Price 0.5~ 800kVA UPS 220/380VAC pro Industriis et Campo Commerciali, PC, Computer/It Room, Data Center Potestatem, unumquemque temporis, notum habuimus in omnibus particularibus, ut singulas res felices a nostris consumerent.
Factory PriceSina UPS et Online UPS His omnibus subsidiis, omnibus emptoribus servire possumus cum qualitate uber et opportuna navigia cum gravissimis officiis. Cum adulescens societas increscens non optimum esse poteramus, sed optimum nostrum socium bonum esse temptavimus.
EXEMPLUM | BNT9010S(H)-33* | BNT9020S(H)-33* | BNT9030S(H)-33* | BNT9040S(H)-33* | BNT9060H-33 | BNT9080H-33 | BNT9100H-33 | BNT9120H-33 | BNT9160H-33 | BNT9200H-33 | |
PERIODO | III, tempus in / III, tempus e | ||||||||||
CAPAX | 10KVA /9KW | 20KVA/18KW | 30KVA/27KW | 40KVA/36KW | 60KVA/54KW | 80KVA/72KW | 100KVA/90KW | 120KVA/108KW | 160KVA/144KW | 200KVA/180KW | |
PARALLEL FACULTAS | usque ad III unitates in parallel | usque ad II unitates in parallel | |||||||||
INPUT | |||||||||||
Nominal Voltage | 3 x 400 VAC (3Ph+N) | ||||||||||
Voltage Range | 190-520 VAC (3-phase) @ 100% load;305-478 VAC (3-phase) @ 100% load | 208-478 VAC (3-phase) @ 70% load;305-478 VAC (3-phase) @ 100% load | |||||||||
Frequentia Range | 46~54 Hz vel 56~64Hz | 40~70Hz | |||||||||
Potestas Factor | 0.99 @ 100% Load | ||||||||||
REFERO | |||||||||||
Output intentione | 3 x 360*/380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | |||||||||
AC Voltage Ordination (Batt. Modus) | ±1% | ||||||||||
Frequentiam dolor (Synchronised dolor) | 46~54Hz vel 56~64Hz | ||||||||||
Frequency Range (Batt. Modus) | 50 Hz ± 0.1 Hz vel 60 Hz± 0.1 Hz | ||||||||||
Current Crest Ratio | 3:1 (max.); | ||||||||||
Harmonic Distortion | ≤2 % THD (Linear Load); ≤4% THD (Locus Non linear) | ≤2 % THD (Linear Load); ≤4% THD (Locus Non linear) | |||||||||
Transfer Tempus | Zero | ||||||||||
Inverter ad bypass | Zero | ||||||||||
Waveform (Batt. Modus) | Purus sine unda | ||||||||||
ONERO | AC Modus | 100-110% pro 10 min, 110-130% pro 1 min,>130% pro 1 secundo | 105-110% pro 1 hr, 111-125% pro 10 min, 126-150% pro 1 min, >150% pro 200ms | ||||||||
Pugna Modus | 100-110% pro 30 secundis, 110-130% pro 10 secundis; | 105-110% pro 1 hr, 111-125% pro 10 min, 126-150% pro 1 min, >150% pro 200ms | |||||||||
PRAESTANTIA | |||||||||||
AC Modus | 95.50% | 94.00% | |||||||||
ECO Modus | 97.00% | 98.00% | |||||||||
Pugna Modus | 93.50% | 93.00% | |||||||||
PUGNA | |||||||||||
Standard Model | Numeri | (16+16) pcs x 1 chorda | (16+16) pcs x 2 chordarum | N/A | |||||||
Typical Recharge Tempus | IX horas recuperandam ad XC% facultatem | ||||||||||
Incurrentes Current (max.) | 1A/2A/3A/4A (Adjustable) | ||||||||||
dato intentione | +/-218 VDC ± 10% | ||||||||||
Donec cursus Model | Type altilium | Secundum facultatem gravida externa | |||||||||
Numeri | XXXII ~ PCs XL (Adjustable) | ||||||||||
Incurrentes Current (max.) | 1A/2A/3A/4A (Adjustable) Parallelable usque ad 3 patina boards usque ad maximum 12A | 2A/4A/6A/8A (Adjustable) Parallelable usque ad 3 mutatoria tabulae dualis patina ad maximam 24A | 24A | 32A | 40A | 48A | |||||
dato intentione | +/- 13.65V x N (N=16~20) | +/- 13.7V x N (N = 16~20) | |||||||||
INDICATORS | |||||||||||
LCD Display | UPS status, onus gradu, altilium gradu, input / Output intentione, officium timer, et culpae conditiones | X "Tange Type color LCD | |||||||||
PHYSICAL | |||||||||||
Standard Model | Dimensio, D x W x H (mm). | 627 x 250 x 750 | 815 x 300 x 1000 | N/A | |||||||
Net Pondus (kg) | 129 | 144 | 225 | 250 | |||||||
Donec cursus Model | Dimensio, D x W x H (mm). | 627 x 250 x 750 | 815 x 300 x 1000 | 790 x 360 x 1010 | 940 x 567 x 1015 | 1040 x 567 x 1452 | |||||
Net Pondus (kg) | 33 | 48 | 60 | 61 | 108 | 113 | 199 | 234 | 306 | 340 | |
ENVIRONMENT | |||||||||||
Operatio Temperature | 0-40°C | ||||||||||
operatio Umor |
| ||||||||||
sonitus Level | Minus than55dB@ 1 Meter | Minus quam 60dB @ I metri | Minus quam 70dB @ I metri | Minus quam 75dB @ I metri | Minus quam 70dB @ I metri | Minus quam 73dB @1 Meter | |||||
MAGISTERIUM | |||||||||||
Dolor RS-232 / USB | Sustinet Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux et MAC. | ||||||||||
Libitum SNMP | Potestas procuratio ex SNMP procurator et web pasco |